MICROSCAN

Microscan IB-105 interface box Microscan IB-105 interface box 

The Microscan IB-105 (interface box), available in five options, is a junction that provides connectivity between the Microscan MS-710 scanner, the host or LAN, power input, and trigger devices.

The box has an internal relay contact (1 watt), a new master pin button to allow input of master label data, a default switch, a power switch, and a mode switch to toggle between RS232 and RS422 or 485 (depending on option).

General Specifications

Mechanical

Length  4.5" (114.3mm)

Width  3" (76.2mm)

Height  1.5" (38.1mm)

Communications  RS232, RS422, RS485

Environmental

Operating temperature  0° to 50°C

Humidity  90% @ 40C maximum

Electrical

Supply voltage input  Regulated +5 VDC @ 20mA

Maximum ripple  200mV p-p with MS-710 +5 VDC @ 500mA

Options

Option -01
Use this option to communicate to the host via RS232 (w/ RTS/CTS or Aux) or RS485.
With Option -01, switch IN, the scanner must be set up for Multidrop communications. Also, pin 4 of the RS232 host connector is not available.

  • Switch OUT: when the Mode switch is OUT, the host port can be used either for RS232 with RTS/CTS to the host (Figure A) or for communicating with an auxiliary terminal and the host without RTS/CTS.

  • Switch IN: when the Mode switch is IN, RS232 is converted to RS485 levels which are present at both the RS422/485 LAN connector and the 25pin "RS232" connector.

Option -02
Use this option to communicate to the host via RS232 (w/ RTS/CTS or Aux) or RS422.

  • Switch OUT: same as Switch OUT of Option -01

  • Switch IN: when the Mode switch is IN, RS232 signals (TXD, RXD) are converted to RS422 levels which are present at both the RS422/485 (LAN) connector and the 25pin "RS232" connector.

Option -03
This option allows a standard RS232 cable to connect pins 2 and 3 to the auxiliary port while host communication is handled by RS422 through the RS422/RS485 port.
With Option -03, the mode switch must be IN for proper operation.

Option -04
This option is designed to work with a special MS-710 scanner that has an internal RS422 chip in place of the standard RS232 chip. The IB-105 converts RS422/485 signals to RS232 for communications to the RS232 for communications to the host. Pins 2 and 3 are the only host (RS232) port pins that are active in this configuration.

Option -05
This is a special option to convert RS422 signals to RS232. It is typically used in long distance (up to 4000 ft) communications in conjunction with another IB-105. The first IB-105 (an -02 option) converts the scanner signals to RS422: the second IB-105 (an -05 option) converts them back to RS232 for communication with the host.
With Option -05, the mode switch, scanner connector, and trigger connector are not used.

Call RACO for the discount price at 800-446-1991!

 

Specifications subject to change without notice.


Back to Microscan main

Back to Accessories main

RACO Industries has competitive prices and quality, guaranteed. View our Manufacturers Listing Page to see a listing of manufacturers with their products that we sell or visit our Home Page to learn more about the products that we carry and about RACO Industries. To hear our most recent low prices just call us at 513-984-2101 or 800-446-1991!

RACO Industries also carries a full line of barcoding printers, supplies, software and accessories. Call for more details!

© RACO Industries. Specifications and prices listed are subject to change without notice. All products and brand names are trademarks of their respective companies. All rights reserved.